Documents and certificatesPrequalificationCareersMadinah, KSA920018640info@tepco-ksa.comالعربية
ProductsServicesManufacturingIndustriesProjectsAboutBusiness unitsLicences and certificatesContact
Talk to an engineerالعربية
Finished low voltage cubicles standing in the hangar at the Madinah plant
Low voltage switchboards

Main, submain and final distribution.

Three families — EPOS, PrismaSeT and distribution boards — designed to IEC 61439, with BlokSeT as the design basis.

6,300 A
BlokSeT, up to
5,000 A
EPOS, up to
4,000 A
PrismaSeT, floor-standing
IEC 61439
Designed to
The families

Three families, one standard.

All three are designed to IEC 61439-1 and -2.

An EPOS switchboard lineup seen along its length, with an APFR relay and a circuit-breaker cubicle on the nearest section
EPOS · TEPCO design

EPOS main distribution boards

Main distribution cubicles, designed by TEPCO rather than licensed in.

  • EPOS cubicles at IP 54, rated up to 5,000 A
  • Designed to IEC 61439-1 and -2
  • Deliberately simple switchboard design
  • Suitable for commercial and industrial environments
  • High safety and reliability of equipment
  • Flexible design for building applications and their operation
Two people fitting breakers onto the busbar inside a board
PrismaSeT International

Main and submain distribution

The layer under the main board: submains, risers, plant rooms and floor distribution.

  • Wall-mounted enclosures at IP 30, 31, 40 and 54, up to 630 A
  • Floor-standing cubicles at IP 30, 31, 42 and 54, up to 4,000 A
  • Schneider Electric LV protection components and switchgear
  • Compact and economical
  • Designed to IEC 61439-1 and -2
  • Suitable for commercial and industrial environments, with total safety for personnel
  • Deliberately simple design, flexible for building applications and their operation
Distribution boards laid out on the floor beside component cartons
Distribution boards

Final distribution, indoor and outdoor

The last enclosure between the network and the load.

  • Indoor and outdoor installation
  • Surface or flush mounting
  • Universal, Load Centre and Disbo ranges
  • Built to the IEC 61439 series
A lineup of EPOS main distribution boards on the shop floor, with a metering and indication cubicle at the centre and a circuit-breaker cubicle to the right
An EPOS board lineup. Configuration per project.
EPOS · technical data

Rated values.

ParameterValue
Rated currentUp to 5,000 A
Degree of protectionIP 54
StandardsIEC 61439-1 and IEC 61439-2
ComplianceDesigned to the standard
Design originTEPCO design
EnvironmentCommercial and industrial
ConfigurationPer project, to the approved single-line diagram
Ratings are configured per project against the approved single-line diagram.
Floor-standing PrismaSeT low voltage switchboard with glazed doors showing the circuit breakers inside
PrismaSeT floor-standing assembly, breakers behind glazed doors. Wall-mounted and floor-standing forms are both built.
PrismaSeT · technical data

Wall-mounted and floor-standing, side by side.

ParameterWall-mounted, indoor · Floor-standing, indoor
Nominal rated current630 A · 4,000 A
Rated insulation voltage Ui1000 V AC
Rated operational voltage415 V AC · Up to 415 V AC
Rated impulse withstand voltage8 kV · 12 kV
Frequency50 / 60 Hz
Main busbar rated current max. Ie630 A · 3200 / 4000 / 4280 A
Rated peak withstand current Ipk53 kA · 220 kA
Degree of protectionIP 30, 31, 40, 54 · IP 30, 31, 42, 54
Electrical characteristics according to IEC 61439-1 and -2. Values are given wall-mounted indoor first, floor-standing indoor second.
A group of distribution boards: surface and flush enclosures of different sizes, one with its door removed
Indoor, outdoor, surface and flush enclosures. Ways and ratings per project.
Distribution boards · technical data

Rated values.

ParameterValue
InstallationIndoor and outdoor
MountingSurface or flush
RangesUniversal · Load Centre · Disbo
StandardsIEC 61439 series
ApplicationFinal and sub-distribution
Ratings and waysConfigured per project, to the approved board schedule
Ratings, ways and ingress rating are configured per project.
Design basis · licence under application

BlokSeT, the Schneider Electric design.

BlokSeT is the Schneider Electric low voltage design TEPCO is applying to manufacture under licence. Form 4 separation means work on one functional unit does not compromise another, which is why it is written into healthcare, data center and critical-process specifications.

It will be manufactured in Madinah on the same protocols, components and quality systems Schneider applies to its own production.

  • Schneider Electric manufacturing licence — under application
  • Designed to IEC 61439-1 and -2
  • Rated current up to 6,300 A
  • Forms of separation up to Form 4
  • Degree of protection up to IP 54
  • Schneider Electric LV protection components and switchgear

Licence status. The Schneider Electric manufacturing licence for BlokSeT is under application and has not yet been issued. BlokSeT is named here as the design basis for low voltage assemblies; manufacture under the licence begins when the licence is granted.

A long line of open low voltage cubicles in the assembly hall
Form 4
Separation, up to
A BlokSeT low voltage distribution and motor control switchboard
WhatsAppBook a call